+86-18822802390

Diode engrenage et diode mesure méthode numérique multimètre

Sep 15, 2023

Diode engrenage et diode mesure méthode numérique multimètre

 

Le diode engrenage est a engrenage que est fréquemment utilisé. Généralement, this gear is found on digital meters. Le logo is a diode symbol, and there may be a symbol similar to "signal" around it. For details, please refer to the representation in the above figure.


Tourner le multimètre à ceci engrenage à voir si le susmentionné "signal" symbol est affiché sur le affichage écran (se référer à le ci-dessus image). In fact, this is a buzzer gear. If the red and black probes are shorted, you will hear the buzzer sound. This gear can be used to measure the on-off of wires, but today we are talking about another one. Pressez the switch button on the digital meter to see a diode symbol displayed on the display screen.


Parce que le stylet rouge du compteur numérique est connecté à le pôle positif de l’alimentation interne alimentation et le noir stylet est connecté à le négatif pôle de l’alimentation interne alimentation, quand mesure la diode avec le numérique mètre, put le rouge stylet on le positif pôle de la diode et connect le noir stylet à le pôle négatif de la diode. Sous normal circonstances, le positif conduction tension chute de ce diode sera affiché on the display screen, for example, the on-state voltage drop of this diode is 0}.607V below.


For a normal diode, the on-voltage drop can be measured, but if the diode is reversed (the red stylus is connected to the cathode of the diode and the black stylus is connected to the anode of the diode), no results can be measured, so the quality of the diode can also be judged by this method. For details, please refer to the measurement results in the following figure.


The diode is measured by taking the ordinary rectifier tube as an example. In fact, this method can fondamentalement be used for other types of diodes. For example, the on-voltage drop of LED lamps (électroluminescent diodes) can also be measured by using this gear.



1. I can't see the specific model of your multimeter clearly;


2. In general digital multimeter, the measured voltage at diode gear is less than 2V, but you are mesurant P6KE36, which is a bidirectional diode. The voltage at diode gear of this diode and multimeter should be at least 6V before measurement, but the diode gear of general digital multimeter can't reach this voltage at all.


3. To put it simply, it is only possible to measure this diode if the voltage between the two probes of the diode is above 6V, and your multimeter can't meet this requirement at all;


4. à mesure ceci diode avec votre multimètre, vous devez utiliser a régulé puissance alimentation avec a tension de plus que 10V, connect a résistance in series, and then connect it in series with this diode to measure whether it is good or bad;


5. As for the series resistance and power resistance, it should be determined according to the normal working current of your diode. I can't give you a specific calculation here.


6. Because the voltage of the diode of your multimeter can't meet the requirements, the positive and negative measurements are not feasible, but it can't prove that the bidirectional diode is broken.


7. To put it simply, this kind of diode can't be measured directly with the diode range of multimeter.

 

3 NCV Measurement for multimter -

 

Envoyez demande